Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13668350

- Product Categories
- Friendly Links
- home > Supply > Shanghai, Guangzhou, Shenzhen AMP AMP UTP cable official website validation / office / test report
Information Name: | Shanghai, Guangzhou, Shenzhen AMP AMP UTP cable official website validation / office / test report |
Published: | 2015-05-18 |
Validity: | 30 |
Specifications: | 1 * 1 |
Quantity: | 2000.00 |
Price Description: | |
Detailed Product Description: | AMP AMP cable manufacturer edit lines are manufactured by TE Connectivity United States, the United States TE Connectivity is a global company with annual sales of $ 12.1 billion. The company designs and manufactures over 500,000 products that connect and protect the flow of power and data inside various products we use every day in. Our nearly 100,000 employees and clients across industries to cooperate. From consumer electronics, energy and healthcare, to automotive, aerospace and communication networks, we use smarter, faster, better technologies to connect products to unlimited possibilities. TE Connectivity 1989 entered China in Shanghai opened its first factory. Currently, TE Connectivity has approximately 38,000 employees in China, it has established 16 production bases, and provide services through a nationwide sales offices in 14 cities to customers. TE Connectivity fiscal year 2010 total sales of $ 1.9 billion in China, accounting for 16% of total annual revenue. 2AMP network cable network cable into taxonomy editor AMP AMP UTP cable, AMP six cable. AMP ultra-five six is ??divided into unshielded (UTP) and shielded (FTP) two kinds. 3AMP cable type editor UTP unshielded cable 6-219507-4 (305 m / box) works with UTP unshielded cable 6-219586-4 (305 m / box) 1427254-6 six unshielded cable (blue color, with a cross skeleton) UTP shielded cable 219413-2 (white, 305 m / box) 1859204-6 six shielded cable (blue, 305 m / axis) 4AMP cable Features Editor AMP cable transmission performance far exceeds TIA / EIA-568B.2-1 six standard and TIA / EIA-568B standard UTP; Impedance: 100ohms ± 15%, IMHzto 600MHz; propagation delay: 536ns / 100m max @ 250MHz; DC resistance:. ≤7.55Ω; resistant Pressure: 300 volts AC or DC; bending radius: 1 inch (4 times the cable diameter); Rated speed: 70 nom%; / NEC rating: CMR; Certification: eligible UL listed file no.E154336; Working temperature: -20 ℃ to a range of 60 ℃; Storage temperature: -20 ℃ to 80 ℃ between comprehensive by FLUKE DSP-4100 transmission performance test standard cable material 5AMP Edit Wire: -23AWG solid bare copper; Insulation: single 042in / overall 20in; jacket: FR PVC; weight: 261bs / mft. AMP cable Applications: for EIA / TIA 568A / B universal linear order; 6AMP cable Applications Editor 1. widely used in network communications media dissemination. 2. supports voice, data, and most of the media high-speed transmission; 3. support 10Base T / 100Base Tx Fast Ethernet, Gigabit Ethernet and a variety of network types 622Mbps ATM, Token Ring and the like. 7AMP true and false identification to edit a network cable, check the cable conductor material lines the market a lot, there are many types of conductive material with copper, copper clad aluminum, copper clad steel, copper coated iron, a good conductor lines are OFC do, prices vary a lot, take the scissors from the line Xinxie angle cut down, look inside whether it contains impurities or other metallic colors, copper network cable generally only in the surface coated with a layer of copper, so that You can save a lot of costs, but will result in a speed and life lines to transmit information. 2, check the network cable flexibility Good quality cable designed to take into account the ease of wiring, try to be very flexible, no matter how easy bending, but not easy to be broken. And currently on the market a lot of profiteers in order to obtain high sales profits, the originally pure copper quality yarn for incorporation of other low-cost metal components, the cost of such lines will drop, but the cable itself, the quality and performance is quite the same phenomenon is manifested lines no longer so soft texture of the cable, the transmission speed of the network cable has been damaged. If the wiring process, the repeated bending this cable, then the copper wire inside the cable might be broken. Of course, if the cable was found too soft, they should note that it may be fake and shoddy products. 3, the test network cable flammability general material network cable must require anti-flammability, what otherwise appears a fire, then it losses a. So everyone in the choice of cable, be sure to check the cable jacket can burn, so as to identify the authenticity. In the specific test, we can first use scissors to cut about 2 cm cable jacket length, and then facing with a lighter skin burn, the skin will be genuine cable barbecue under the fireworks, gradually melt deformation, but certainly not their own skin burn up; if found cable sheath can not help the test of fire, a little on the burn, then the transmission speed of cable no matter how high it should abandon choice, after such a network cable in the wiring project is very safe, the use of it will stay Under great security risk. I once got some genuine cable and inferior cable, while lit with a lighter they found that 6 seconds, the genuine cable is white smoke and, over time, gradually melt deformation, while the inferior cable less than 2 seconds, It is easily ignited, and accompanied by a large number of black smoke. 4, temperature resistance wiring project to test the network cable in to the cable against external temperature changes have a very high demand, do not say resistant to any environmental change it, at least the network cable is not at high or low temperatures are softened or is cracking. In order to ensure performance at high temperatures affected the network cable, genuine cable jacket materials used can withstand temperatures up to 50 degrees test, it does not appear to be softening similar to cable or deformation of the phenomenon. If the interception of a short cable jacket, placed next to the stove for some time, found that the skin than normal skin soft, then it shows the quality of the network cable, but definitely hard. 5, signs identifying the cable jacket on in the actual selection of cable, it is sometimes a lack of environmental or conditional test, when unable to mass or material lines were tested by the above methods, you may wish to identify the network cable by identifying observe the cable jacket on for authenticity. Under normal circumstances, the regular brand cable jacket has a kind of logo and trademarks of manufacturers of network cable, such as CAT5 logo that indicates that the network cable is five lines; CAT5E on behalf of the network cable is UTP cable; CAT6 logo on behalf of the cable is six line; if the network cable jacket to identify what has not, then we should be vigilant and try to create the conditions to follow the above method for testing cable identification. 6, test lines around the pitch We all know that ordinary twisted pair is connected by four lines intertwined together. About the fact that the network cable from one section of the length of New Zealand Rao called network cable, usually people use around the pitch to represent each of the lines of how closely intertwined, and in order to be able to level the crosstalk between each pair of lines generated with each other to minimize , often pairs counterclockwise closely intertwined, and each wire pair used around the pitch should not be the same. But many production lines in order to reduce production components profiteers, reduce technology costs, often in accordance with the same four pairs of lines on the pitch were wound around, and even many low-quality cables around as high as a few centimeters away from the crosstalk between pairs so big increase, seriously affecting the performance of the network cable. 7, stretch the skin test Taking into account the cable wiring often need to bend, many regular cable manufacturers in the production of skin left gave some stretching, to ensure that the cable is not damaged when bent. So when we pull the regular network cable with both hands, both have found skin stretch. If forced off the network cable outside Pyla, or skin in the external force, there are cracks in the phenomenon, then it shows the quality of the network cable problems. |
Admin>>>
You are the 20754 visitor
Copyright © GuangDong ICP No. 10089450, InBev Guangzhou Communication Equipment Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 20754 visitor
Copyright © GuangDong ICP No. 10089450, InBev Guangzhou Communication Equipment Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility